Our ELISA kit quality assurance, excellent quality, affordable, is your first choice for biological experiments, if you need to contact our sales staff.
This reagent is for research use only: This kit is used to detect porcine leptospira antibody IgG (Lep-IgG) levels in pig serum.
Experimental principle :
This kit uses double antigen sandwich enzyme-linked immunosorbent assay (ELISA) to determine the antibody (Lep-IgG) of Leptospira interrogans in specimens. The microtiter plate is coated with the purified antigen to prepare a solid phase antigen, which can be combined with the Leptospira antibody IgG (Lep-IgG) in the sample, washed to remove unbound antigen and other components, and then HRP-labeled antigen. The antigen-antibody-enzyme-labeled antigen complex is formed by binding, and after thorough washing, the substrate TMB is added for color development. TMB is converted to blue under the catalysis of HRP enzyme and converted to the final yellow color by the action of an acid. The absorbance (OD value) was measured at 450 nm using a microplate reader, and compared with the CUTOFF value to determine the presence or absence of the Leptospira antibody IgG (Lep-IgG) in the specimen.
Kit composition :
Kit composition | 48 hole configuration | 96-well configuration | save |
Instruction manual | 1 copy | 1 copy | |
Sealing film | 2 pieces (48) | 2 pieces (96) | |
sealed bag | 1 | 1 | |
Enzyme label coated plate | 1×48 | 1×96 | Store at 2-8 ° C |
Negative control | 0.5ml × 1 bottle | 0.5ml × 1 bottle | Store at 2-8 ° C |
Positive control | 0.5ml × 1 bottle | 0.5ml × 1 bottle | Store at 2-8 ° C |
Enzyme standard reagent | 3 ml × 1 bottle | 6 ml × 1 bottle | Store at 2-8 ° C |
Sample diluent | 3 ml × 1 bottle | 6 ml × 1 bottle | Store at 2-8 ° C |
Developer A solution | 3 ml × 1 bottle | 6 ml × 1 bottle | Store at 2-8 ° C |
Developer B solution | 3 ml × 1 bottle | 6 ml × 1 bottle | Store at 2-8 ° C |
Stop solution | 3ml × 1 bottle | 6ml × 1 bottle | Store at 2-8 ° C |
Concentrated washing solution | (20ml × 20 times) × 1 bottle | (20ml × 30 times) × 1 bottle | Store at 2-8 ° C |
Sample processing and requirements :
1. Serum: The blood is naturally coagulated for 10-20 minutes at room temperature and centrifuged for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if precipitation occurs during storage, it should be centrifuged again.
2. Plasma: EDTA or sodium citrate should be selected as an anticoagulant according to the requirements of the specimen. After mixing for 10-20 minutes, centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again.
3. Urine: Collect with a sterile tube and centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. The chest and ascites and cerebrospinal fluid are referred to.
4. Cell culture supernatant: When detecting secreted components, collect them in a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When the components in the cells were detected, the cell suspension was diluted with PBS (pH 7.2-7.4), and the cell concentration reached about 1 million/ml. By repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.
5. Tissue specimen: After cutting the specimen, weigh the weight. Add a certain amount of PBS, pH 7.4. It was quickly frozen and stored in liquid nitrogen for use. The specimen still maintains a temperature of 2-8 ° C after melting. A certain amount of PBS (pH 7.4) was added, and the specimen was homogenized by hand or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. One part of the package is to be tested, and the rest is frozen for use.
6. The specimens should be extracted as soon as possible after collection, and the extraction should be carried out according to the relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 °C, but repeated freezing and thawing should be avoided.
7. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
Operation steps :
The result is judged:
Test validity: mean value of positive control well ≥ 1.00; mean value of negative control ≤ 0.10
CUT OFF calculation: critical value = negative control well average + 0.15
Negative judgment: Sample OD value < CUT OFF is negative for human Leptospira antibody IgG (Lep-IgG)
Positive judgment: sample OD value ≥ critical value (CUT OFF) is human Leptospira antibody IgG (Lep-IgG) positive
Precautions
1. The operation is carried out in strict accordance with the instructions. The components of the different batches of this reagent shall not be mixed.
2. The kit should be taken out from the refrigerated environment and should be used at room temperature for 15-30 minutes before use. If the enzyme label is unsealed after opening, the slats should be stored in a sealed bag.
3. Concentrated washing liquid may crystallize out. When diluted, it can be heated and dissolved in a water bath. The washing will not affect the result.
5. Please keep the substrate away from light.
6. The test results must be determined by the microplate reader. When using dual-wavelength detection, the reference wavelength is 630nm.
7. All samples, washings and various wastes should be treated as infectious materials. The stop solution is 2M sulfuric acid and must be used safely.
Storage conditions and expiration date
1. The kit is stored at: 2-8 °C.
2. Validity: 6 months
What is Indoor PTZ Camera
PTZ: In the security monitoring application, it is the abbreviation of Pan/Tilt/Zoom, representing the pan tilt omnidirectional (up and down, left and right) movement, lens zoom and zoom control.
PTZ: In the security monitoring application, it is the abbreviation of Pan/Tilt/Zoom, representing the pan tilt omnidirectional (up and down, left and right) movement, lens zoom and zoom control.The automatic PTZ tracking and monitoring system integrates optics, electronics, machinery, information processing and network, and is composed of camera, power transmission, motion control device, image analysis, recognition, compression and communication based on high-speed parallel processing. It has the functions of video camera, position control, orientation and lens preset, moving object detection, recognition and tracking, flame and smoke detection and alarm, etc. It can be widely used in buildings, banks, airports, stations, customs, transportation, power, factories and mining enterprises and other security monitoring occasions.
Indoor PTZ Camera,Indoor PTZ Camera,Surveillance Wireless Security Camera,Wireless Security CCTV
Indoor Wifi HD PTZ Camera,Indoor PTZ Camera Security,Surveillance Wireless Security Camera,Wireless Security CCTV
Shenzhen Fuvision Electronics Co., Ltd. , https://www.outdoorsolarcameras.com